Calcaneus, Malleolar, Wrist, Diaphyseal Humerus, Distal Humerus, Humerus Claw, Olecranon, Radius-Ulna, Distal Femur, Tibia, PFF, Periprosthetics

periprotesiche


The design of periprosthetic plates has to overcome a number of technical issues. There is a high incidence of mobilisation of plates in multiple fractures, the presence of a prosthesis makes screw positioning difficult, and poor quality bone often results in screw pull-out and an early breakdown of the fracture.

Intrauma has developed a range of plates specifically for the treatment of periprosthetic fractures of the hip, knee and humerus. The use of O’nil periprosthetic plates ensures secure fixation of the fracture, early patient mobilisation and fracture healing times similar to normal fractures.

The patented conical screw locking system between the head of the screw and the holes in the plate ensures primary stability by equally distributing the forces along the length of the plate. Pre-shaped plates with a semi-tubular profile simplify plate positioning and the multi-planar screw holes ensure optimum fixation even in more complex fractures.

The O’nil Iron Lady plate for periprosthetic fractures of the hip is a self-supporting structure where cerclage can be used simply to fix fragments in place rather than to support the plate. As with other O’nil plates, the unique screw locking mechanism minimises pressure on the bone, helping to preserve the vascularity of the periosteum, allowing early rehabilitation and reducing healing time.

PERIPROSTETIC FRACTURES OF HIP

  • Anatomically pre-shaped low-profile semi-tubular plates
  • Multi-planar screw holes simplify plate positioning and ensure primary stability
  • Plates made of steel AISI 316 LVM – ISO 5832-1, to allow MRI, screws and bushings made of titanium Ti6AI4V – ISO 5832-3
  • Cerclage option using eyelet with conical locking

PERIPROSTHETIC FRACTURES OF HUMERUS

  • Anatomically pre-shaped low-profile semi-tubular plate
  • Multi-planar screw holes provide primary stability
  • Simple and intuitive instruments
  • Plates made of steel AISI 316 LVM – ISO 5832-1, to allow MRI, screws and bushings made of titanium Ti6AI4V – ISO 5832-3
  • Reduced surgical time

PERIPROSTEHIC FRACTURES OF KNEE

  • The patented screw-plate locking system eliminates the possibility of cross-threading between the head of the screw and the plate
  • Anatomically pre-shaped low-profile semi-tubular plate
  • 6 holes in the distal part of the plate provide excellent fixation even in osteoporotic bone
  • Plates made of steel AISI 316 LVM – ISO 5832-1, to allow MRI, screws and bushings made of titanium Ti6AI4V – ISO 5832-3
  • Available in 2 lengths, in right and left versions

LINKED PRODUCTS

PHF – Proximal Humerus Fixator
An excellent solution for fractures of the humeral head
PFF
Proximal femur plate with modular greater trochanter hook
Excellence – Proximal tibia
Anatomical plates for proximal tibia fractures

SupportRefL. mmTh. mmHoles
Iron Lady Extra Curved135.10003003.018
Iron Lady One135.10012003.014
Iron Lady Plus Curved135.10042503.016
Diaphyseal Humerus 10135.10061452.510
Periarticular 14 L152.30032504.06+8
Periarticular 14 R152.30042504.06+8
Periarticular 17 L152.30053254.06+11
Periarticular 17 R152.30063254.06+11
Eyelet 3,5130.3200
Eyelet 5150.4500
Threaded Eyelet 5150.4501
ScrewsøL. mm
Autolocking screws3.5mm10mm to 70mm
ScrewsøL. mm
Autolocking screws5mm12mm to 110mm
InstrumentsRef
Instrument tray 3.5 and 5 SeriesS30, S500