Calcaneus, Malleolar, Wrist, Diaphyseal Humerus, Distal Humerus, Humerus Claw, Olecranon, Radius-Ulna, Distal Femur, Tibia, PFF, Periprosthetics
Prev 1 2 3 4 5 6 Next
13th EFORT Congress 2012

13th EFORT Congress 2012

Congress venue: Messe Berlin GmbH Internationales Congress Centrum ICC Berlin
Main entrance: Neue Kantstrasse/corner of Messedamm
14057 Berlin
Germany

Link: http://www.efort.org/berlin2012/
Programme: http://www.efort.org/berlin2012/2_programme_scientific.aspx

Exhibition floor plan
Booth specification

Continue Reading

O’nil

O’nil

The company designs and manufactures the O’nil range of locking plates in collaboration with experienced trauma surgeons. Our aim is to provide the highest quality implants and to simplify today’s approach to Traumatology.

The O’nil range of locking plates have a unique patented locking system using a tapered, conical coupling. This system offers many advantages over traditional locking plates and overcomes many of the problems associated with traditional non-locking and locking plate systems.

Continue Reading

PHF – Proximal Humerus Fixator

PHF – Proximal Humerus Fixator

The O’Nil plate for proximal humerus is an optimal solution for the treatment of fractures of humeral head. In the proximal part of the plate seven screws can be locked at different angles, providing maximum stability to the humeral head, granting excellent grip in the osteoporotic bone and in multi fragmentary fractures.

Made of AISI 316 LVM – ISO 5832-1 steel to allow MR imaging, the low profile and the particular design reduce the risk of impingement.

Continue Reading

Periprosthetics

Periprosthetics

The supports implanted into the periprostetics have often high incidence of mobilization caused by multiple factors; among the most frequent technical difficulty in stabilizing the fracture of the stem, which prevents easy positioning of the screws.

Continue Reading

Kite – Malleolar plate

Kite – Malleolar plate

The O’nil Kyte system allows a perfect reduction of the lateral malleolus and includes plates of 3 different lengths.

The elliptical hole in the diaphyseal area allows fibular malleolus sindesmosis using a standard screw.

The unique conical screw-plate locking mechanism ensures fracture stability whist avoiding pressure on the bone, preserving vascularity and accelerating the return of the patient’s previous mobility and function.

Continue Reading

Calcaneus

Calcaneus

The calcaneus is the most frequently fractured tarsal bone, with 70-75% of fractures being intra-articular. fractures with collapse and imposed serious fractures Open reduction and stable internal fixation with a lateral plate is a standard treatment for such intra-articular fractures.

Continue Reading